高级检索

Ti-Mo吸气剂材料真空性能研究

Vacuum Properties of Ti-Mo Getter Material

  • 摘要: 加速器基硼中子俘获治疗( AB-BNCT )是一种新型治疗肿瘤方式。离子源进气时低真空易引发加速器打火问题亟待解决,实现束流传输通道高真空是保障加速器稳定运行的关键。非蒸散型吸气剂泵(NEG)体积较小,对氢抽速大,高电位适用性强,是实现直流高压加速器束流传输通道高真空及超高真空环境的重要方式之一。NEG泵性能受激活次数、工作温度、氢分压、杂质气体、粒子辐照及高电压等因素影响。采用定压法研究激活循环、稳态工作温度和氢分压对Ti-Mo吸气剂单位质量吸气速率和吸气容量的影响,并结合Sieverts定律及微观组织分析吸脱附平衡与性能衰减。结果表明,吸气剂在第二次活化循环后表现出最高的吸气性能。在所研究的范围内,提高工作温度或氢气分压会不同程度地提升初始吸气速率和吸气容量。在本研究采用的氢气负载和压力条件下,Ti–Mo吸附剂在约350℃时接近动态吸附-脱附平衡,而在450℃时,氢气脱附成为主导。

     

    Abstract: Accelerator-based boron neutron capture therapy (AB-BNCT) is an emerging modality for cancer treatment. Vacuum deterioration caused by gas injection into the ion source may induce electrical breakdown in the accelerator. Maintaining a high vacuum in the beam transport line is therefore essential for stable accelerator operation. Non-evaporable getter (NEG) pumps feature a compact size, a high pumping speed for hydrogen, and good compatibility with high electric potentials, making them suitable for establishing high- and ultrahigh-vacuum conditions in the beam transport lines of direct-current high-voltage accelerators. The pumping performance of NEG pumps is affected by activation cycles, operating temperature, hydrogen partial pressure, impurity gases, particle irradiation, and high voltage. In this study, the constant-pressure method was employed to investigate the effects of activation cycles, steady-state operating temperature, and hydrogen partial pressure on the specific pumping speed and sorption capacity of a Ti–Mo getter. The adsorption–desorption equilibrium and performance degradation were further analyzed based on Sieverts’ law and microstructural characterization. The results show that the Ti–Mo getter exhibited its highest pumping performance after the second activation cycle. Within the investigated ranges, increasing the operating temperature or hydrogen partial pressure enhanced both the initial specific pumping speed and sorption capacity to varying degrees. Under the hydrogen-loading and pressure conditions employed in this study, the Ti–Mo getter approached a dynamic adsorption–desorption equilibrium at approximately 350℃, whereas hydrogen desorption became dominant at 450℃.

     

/

返回文章
返回