高级检索

小直径潘宁离子源的脉冲时幅特性研究

Pulse Amplitude-Time Characteristics of Small-Diameter Penning Ion Source

  • 摘要: 针对小直径脉冲中子石油测井需求,开展了阳极直径小于10 mm的潘宁离子源脉冲工作特性研究。研究重点在于不同磁感应强度分布与放电间隙结构下,小直径潘宁离子源的脉冲时幅特性。研究结果表明,通过将对阴极间隙的磁感应强度提升到与阴极间隙相当的水平,可以将脉冲电流幅值提升至1 mA以上,同时将延迟时间缩短至20 μs以内。放电增强带来了不稳定脉冲放电及幅值跳变现象,阴极间隙和对阴极间隙的微调对其有显著影响。采用阴极间隙为1.0 mm、对阴极间隙为2.0 mm的结构时,离子源可实现较好的电流幅值、延迟时间及稳定的工作电压范围。在7.0×10−2 Pa至2.0×10−1 Pa的气压范围内,离子源能够获得1 mA至3.5 mA的电流幅值,且延迟时间控制在20 μs以内,最短可达5 μs。

     

    Abstract: In response to the demand for small-diameter pulsed neutron logging in petroleum exploration, this study investigates the pulsed operational characteristics of a Penning ion source with an anode diameter smaller than 10 mm. The focus is on how the distribution of magnetic induction strength and the structure of the discharge gap affect the pulse amplitude-time characteristics of the small-diameter Penning ion source. The results show that by increasing the magnetic induction strength of the anticathode gap to a level comparable to that of the cathode gap, the pulse current amplitude can be raised above 1 mA, and the delay time can be reduced to less than 20 μs. The discharge enhancement brings about the phenomena of unstable pulse discharge and amplitude jumps, which are significantly affected by the fine tuning of the cathode gap and the anticathode gap. With a cathode gap of 1.0 mm and an anticathode gap of 2.0 mm, the ion source can achieve favorable current amplitude, delay time, and voltage range for stable discharge. Within a pressure range of 7.0×10−2 Pa to 2.0×10−1 Pa, the ion source can deliver current amplitudes between 1 mA and 3.5 mA, with delay times maintained below 20 μs, and a minimum delay time of 5 μs.

     

/

返回文章