高级检索

低气压下占空比对细长管空心阴极辉光放电电流的影响

Effect of Duty Ratio on Glow Discharge Current of Hollow Cathode in Slender Tube at Low Pressure

  • 摘要: 为了在细长管内壁获得性能良好质地均匀的膜层,本文在低气压条件下、采用细长管作真空阴极进行空心阴极辉光等离子体放电。通过研究对多种气氛(纯Ar、纯N2、氮气氩气混合)下平均电流、电流峰值的实时测量对比了不同脉冲占空比条件下等离子体放电流,讨论和分析了多气氛下改变占空比所带来的影响。实验结果显示使用频率为40 kHz的脉冲电源,随着占空比变化,脉冲电流波形有显著变化。不同气氛波形不同,但是峰值均提高,平均电流也都上升,纯Ar气氛从20%占空比提高到70%占空比电流峰值从0.325 A上升到了0.5 A,平均电流由0.12 A上升到了0.28 A。测量管内不同位置电流的值,发现管内整体电流均匀性纯Ar和混合气氛优于纯N2,Ar在30%~60%占空比区间内,表征均匀性的参数K30%~60%≈0.12。

     

    Abstract: In order to obtain the film with good performance and uniform texture on the inner wall of slender tube, hollow cathode glow plasma discharge was carried out by using slender tube as vacuum cathode under low pressure. By studying the real-time measurement of average current and current peak under various atmospheres(pure Ar, pure N2, nitrogen and argon), the discharge current of plasma under different pulse duty cycle conditions was compared, and the influence of changing duty cycle under multiple atmospheres was discussed and analyzed.The experimental results show that the pulse current waveform changes significantly with the change of duty cycle when using a pulse power source with a frequency of 40 kHz. The waveforms of different atmospheres are different,but both the peak values and the average current increase. The pure Ar atmosphere increases from 20% duty cycle to 70% duty cycle, and the peak current increases from 0.325 A to 0.5 A, and the average current increases from 0.12 A to 0.28 A. It is found that the overall current uniformity of pure Ar and mixing atmosphere is better than that of pure N2. Ar is in the range of 30%~60% duty cycle, and the parameter k30% ~60% is 0.12.

     

/

返回文章
返回